SYSTEM TROUBLE - A System Trouble display will be followed by one or more of the following error codes:
E01-00 - AC POWER FAIL.
Power failure. Check power transformer. Check for blown fuse or circuit breaker; general power outage.
​
E02-00 - LOW BATTERY.
Battery below 11 volts. If not recharged within 24 hours, replace it.
E03-00 - COMMUNICATION FAIL.
Unsuccessful communication to central station. Note: Will also display if panel improperly
programmed to report; i.e., Report Alarm, Report Codes, Subscriber ID Numbers, etc. must be programmed.
E04-NN - WIRELESS TROUBLE.
Wireless transmitter supervisory failure. NN = transmitter number.
E05-NN - WIRELESS LOW BATTERY.
Rf transmitter low battery. NN = transmitter number.
E06-NN - RF REC TROUBLE.
Rf receiver response trouble. NN = receiver number.
​
E08-00 - TELCO LINE1 FAIL.
This may mean your "land line" has been disconnected. If this message appears after you have had any change in your phone service,
call 651-653-1001
Telephone line failure. Contact your telephone provider.
​
E10-NN - BURG KEYPAD TRBL.
Keypad response failure. NN = keypad number.
​
E15-NN - WIRELESS TAMPER.
Transmitter cover removed. NN = transmitter number.
​
E18-NN - LOBATT KEYFOB.
Key fob transmitter low battery. NN = key fob transmitter number.
​
​
​
If you have a code that is not listed, call 651-653-1001